Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
PLoS One ; 16(9): e0255878, 2021.
Article in English | MEDLINE | ID: covidwho-1440985

ABSTRACT

BACKGROUND: The COVID-19 pandemic illuminated the benefits of telemedicine. Self-collected specimens are a promising alternative to clinician-collected specimens when in-person testing is not feasible. In this study, we assessed the adequacy of self-collected pharyngeal and rectal specimens for the detection of Chlamydia trachomatis and Neisseria gonorrhoeae among individuals undergoing chlamydia and gonorrhea screening. METHODS: We used data from a large cohort study that included male and female adolescents between the ages of 12-24 years. We considered self-collected specimens adequate for clinical use if the human synthase gene (a control target of the assay) was detected in the specimen. RESULTS: In total, 2,458 specimens were included in the analysis. The human synthase gene was detected in 99.2% (2,439/2,458) of all self-collected specimens, 99.5% (1,108/1,114) of the pharyngeal specimens, and 99.0% (1,331/1,344) of the rectal specimens. CONCLUSION: Self-collected pharyngeal and rectal specimens demonstrated a very high proportion of human gene presence, suggesting that self-collection was accurate. A limitation of this study is that the sample adequacy control detects the presence or absence of the human hydroxymethylbilane synthase gene, but it does not indicate the specific anatomic origin of the human hydroxymethylbilane synthase gene. Self-collected specimens may be an appropriate alternative to clinician-collected specimens.


Subject(s)
Chlamydia Infections/diagnosis , Chlamydia trachomatis/isolation & purification , Gonorrhea/diagnosis , Neisseria gonorrhoeae/isolation & purification , Specimen Handling , Adolescent , Child , Chlamydia Infections/microbiology , Female , Gonorrhea/microbiology , HIV Infections , Humans , Male , Pharynx/microbiology , Polymerase Chain Reaction , Rectum/microbiology , Self Care , Young Adult
2.
J Int AIDS Soc ; 24(9): e25801, 2021 09.
Article in English | MEDLINE | ID: covidwho-1396894

ABSTRACT

INTRODUCTION: Provider-collected swabs are an unappealing procedure for many transgender women and may have led to suboptimal rates of Chlamydia trachomatis (CT) and Neisseria gonorrhoeae (NG) testing. Self-collection for CT/NG testing is recommended for men who have sex with men. However, the information on acceptability and clinical performance to support a recommendation for transgender women is lacking. We aimed to determine the acceptability and satisfaction towards self-collection for CT/NG testing among Thai transgender women. METHODS: Thai transgender women who attended Tangerine Clinic (a transgender-led, integrated, gender-affirming care and sexual health services clinic in Bangkok, Thailand) between May and July 2020 and had condomless sexual intercourse within the past six months were offered to collect urine and perform self-swabs of pharyngeal, rectal, and if applicable, neovaginal compartments for pooled nucleic acid amplification testing for CT/NG infections. Participants received a diagram, video and oral instructions about how to perform self-collection procedure. Those who accepted self-collection were also offered to receive provider collection to evaluate the performance between the two methods. Self-administered questionnaires were used to assess satisfaction. RESULTS: Among 216 transgender women enrolled, 142 (65.7%) accepted self-collection. All who accepted had pharyngeal, rectal and urine samples collected. Of 31 transgender women who had undergone genital surgery, 28 (90.3%) accepted neovaginal self-swab. The acceptance rate increased from 46.2% in May to 84.5% in July 2020. One participant had an invalid result. All transgender women who accepted self-collection could perform it without assistance, and 82.8% were highly satisfied with the method. None reported dissatisfaction. Due to the COVID-19 pandemic, provider collection services were discontinued early, and only eight transgender women were able to perform both methods for performance evaluation. The performance agreement was 100%. CONCLUSIONS: Thai transgender women had high acceptability and satisfaction towards self-collection for CT/NG testing. The performance was promising compared to provider collection. Our results support the implementation of self-collection to the sexually transmitted infection services, particularly during the COVID-19 pandemic where physical distancing is the new normal. A larger study is warranted to determine the performance of self-collection for CT/NG testing in each anatomical compartment and confirm the performance between self-collection and provider collection.


Subject(s)
Chlamydia Infections/diagnosis , Chlamydia trachomatis/isolation & purification , Gonorrhea/diagnosis , Neisseria gonorrhoeae/isolation & purification , Patient Acceptance of Health Care , Personal Satisfaction , Specimen Handling/methods , Transgender Persons , Adult , COVID-19 , Chlamydia Infections/epidemiology , Female , Gonorrhea/epidemiology , Humans , Male , Pandemics , SARS-CoV-2 , Self Care , Thailand/epidemiology
3.
Biosens Bioelectron ; 192: 113503, 2021 Nov 15.
Article in English | MEDLINE | ID: covidwho-1309167

ABSTRACT

The COVID-19 pandemic has unfortunately demonstrated how easily infectious diseases can spread and harm human life and society. As of writing, pandemic has now been on-going for more than one year. There is an urgent need for new nucleic acid-based methods that can be used to diagnose pathogens early, quickly, and accurately to effectively impede the spread of infections and gain control of epidemics. We developed a flap probe-based isothermal nucleic acid amplification method that is triggered by recombinant FEN1-Bst DNA polymerase, which-through enzymatic engineering-has both DNA synthesis, strand displacement and cleavage functions. This novel method offers a simpler and more specific probe-primer pair than those of other isothermal amplifications. We tested the method's ability to detect SARS-CoV-2 (both ORF1ab and N genes), rotavirus, and Chlamydia trachomatis. The limits of detection were 10 copies/µL for rotavirus, C. trachomatis, and SARS-CoV-2 N gene, and 100 copies/µL for SARS-CoV-2 ORF1ab gene. There were no cross-reactions among 11 other common pathogens with characteristics similar to those of the test target, and the method showed 100% sensitivity and 100% specificity in clinical comparisons with RT-PCR testing. In addition to real-time detection, the endpoint could be displayed under a transilluminator, which is a convenient reporting method for point-of-care test settings. Therefore, this novel nucleic acid senor has great potential for use in clinical diagnostics, epidemic prevention, and epidemic control.


Subject(s)
Biosensing Techniques , Chlamydia trachomatis/isolation & purification , Rotavirus/isolation & purification , SARS-CoV-2/isolation & purification , COVID-19 , DNA, Recombinant , DNA-Directed DNA Polymerase , Flap Endonucleases , Humans , Nucleic Acid Amplification Techniques , Pandemics , Sensitivity and Specificity
SELECTION OF CITATIONS
SEARCH DETAIL